Blind spacers, type Р for substations

Spacers, type Р are intended for fixing and holding of two wires of the bundle phase conductor of busbars in outdoor switchyard of high voltage substations at the given distance. Substation spacers, type Р meet the requirements of TU U 31.2-30255335-002:2006.

Mark Mark of wire Diameter of a wire, mm Dimensions, mm Weight, kg
А і АКП АС, АСКС, АСКП, АСК ПМ L d
Р-2-120 300; 350; 400; 450 185/128; 240/32; 240/39; 240/56; 300/39; 300/48; 300/66; 330/30; 330/43; 400/22; 300/67; 400/18 21,6-26,6 153 25 0,472
Р-3-120 500; 550 300/204; 400/51; 400/64; 400/93; 450/56; 500/26; 500/27; 500/64 240 27,5-30,6 158 30 0,482
Р-4-120 600; 650; 700; 750; 800 500/204; 500/336; 550/71; 600/72; 650/79; 700/86; 750/93 300 31,5-37,7 164 36 0,526