Blind spacers, type Р for substations
Spacers, type Р are intended for fixing and holding of two wires of the bundle phase conductor of busbars in outdoor switchyard of high voltage substations at the given distance. Substation spacers, type Р meet the requirements of TU U 31.2-30255335-002:2006.
| Mark | Mark of wire | Diameter of a wire, mm | Dimensions, mm | Weight, kg | |||
| А і АКП | АС, АСКС, АСКП, АСК | ПМ | L | d | |||
| Р-2-120 | 300; 350; 400; 450 | 185/128; 240/32; 240/39; 240/56; 300/39; 300/48; 300/66; 330/30; 330/43; 400/22; 300/67; 400/18 | – | 21,6-26,6 | 153 | 25 | 0,472 |
| Р-3-120 | 500; 550 | 300/204; 400/51; 400/64; 400/93; 450/56; 500/26; 500/27; 500/64 | 240 | 27,5-30,6 | 158 | 30 | 0,482 |
| Р-4-120 | 600; 650; 700; 750; 800 | 500/204; 500/336; 550/71; 600/72; 650/79; 700/86; 750/93 | 300 | 31,5-37,7 | 164 | 36 | 0,526 |